Doric 1000 ProThe new Doric 1000 Series digital panel meters are suitable for a wide range of display applications. Designed as a low-cost solution, they offer ruggedness and reliability for many current, voltage, frequency and process applications. A full range of inputs can be measured simply by selecting the proper externally accessible terminals located at the rear of the unit. The decimal point location can be changed by moving the jumpers behind the detachable faceplate. Doric 1000 Series consists of seven models measuring DC Voltage, AC Voltage, DC current, high AC current, high DC current, scalable process and frequency inputs. Engineering unit labels are supplied to indicate measured value. The high DC current model 1000-XDCA is used with 60 mV, 100 mV, 150 mV shunts, and the high AC current model 1000-XCTV is used with 1 A or 5 A current transformers. An alarm setpoint option provides for Hi and Lo (dual) alarm with 5A relays that can be hooked up to on/off control elements. A front panel LED illuminates when the alarm trips. In addition, an optional DC Excitation power supply which provides 30mA at 10 Vdc can also be specified when ordering the Doric 1000 Series. |
| General Specifications |
Size (H x W x L)
Case (1/8 DIN): 1.57" x 3.54" x 4.56" (4.0 cm x 9.0 cm x 10.9 cm)
|
| General Specifications | |||
| Input | Accuracy | (±)* Range | Resolution |
| DC Volts | 0.5% 0.5% 0.5% 0.5% 0.5% |
0 to
±199.9 mV 0 to ±1.999 V 0 to ±19.99 V 0 to ±199.9 V 0 to ±600 V |
0.1 mV
dc 1 mV dc 10 mV dc 0.1 Vdc 1 Vdc |
| AC Volts | 0.5% 0.5% 0.5% 0.5% 0.5% |
0 to
199.9 mV 0 to 1.999 V 0 to 19.99 V 0 to 199.9 V 0 to 600 V |
0.1 mV
ac 1 mV ac 10 mV ac 0.1 Vac 1 Vac |
| DC Current | 0.5% 0.5% 0.5% 0.5% 0.5% |
0 to
±1.999 mA 0 to ±19.99 mA 0 to ±199.9 mA 0 to ±1.999 A 0 to ±5.00 A |
1 µA
dc 10 µA dc 100 µA dc 1 mA dc 10 mA dc |
| High
DC Current Requires 60 mV, 100 mV and 150 mV shunts. (not included) |
0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% |
0 to
±50 A 0 to ±100 A 0 to ±200 A 0 to ±500 A 0 to ±1000 A 0 to ±1500 A 0 to ±2000 A |
0.1 A 0.1 A 0.1 A 1 A 1 A 1 A 1 A |
| High
AC Current Requires 1A or 5A current transformers. (not included) |
0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% |
0 to
±50 A 0 to 100 A 0 to 200 A 0 to 500 A 0 to 1000 A 0 to 1500 A 0 to 2000 A |
0.1 A 0.1 A 0.1 A 1 A 1 A 1 A 1 A |
| Process | 0.5% 0.5% 0.5% |
0-20
mA, 4-20 mA 0-5 Vdc, 1-5 Vdc 0-10 Vdc |
1 count
of ±1999 counts 1 count of ±1999 counts 1 count of ±1999 counts |
| Frequency | 0.5% | 0-1 kHz | 1 Hz** |
| *
Accuracy ±1 digit ** Input voltage: 50 mV to 600 V |
|||